DISASSEMBLY AND ASSEMBLY
FUSER
392
4.9.3  HARNESS ASSY MCU C/L 
REMOVAL
1.
Remove FUSER ASSY. 
2.
Remove COVER ASSY LH. 
3.
Remove CHASSIS ASSY ESS. 
4.
Disconnect the connector (black-and-white) from PWBA FUSER CONT.
5.
Disconnect connector (P417) from PWBA MCU.
6.
Remove the 2 screws (silver, with flange, 6 mm) fastening BRACKET-RIZ to the 
main unit, remove the harness from the clamp, and remove BRACKET-RIZ from 
the main unit.
7.
Draw out HARNESS ASSY MCU C/L from BRACKET-RIZ while pressing the 
claw on HARNESS ASSY MCU C/L.
REINSTALLATION
1.
Insert the claw on HARNESS ASSY MCU C/L into the hole on BRACKET-RIZ 
to attach.
2.
Fasten BRACKET-RIZ to the main unit with the 2 screws (silver, with flange, 6 
mm), and fasten each harness with the clamps.
3.
Attach the harness (yellow) to the connector (P417) on PWBA MCU.
4.
Connect the harness (black-and-white) to PWBA FUSER CONT.
5.
Attach CHASSIS ASSY ESS. 
6.
Attach COVER ASSY LH. 
7.
Attach FUSER ASSY. 
Figure 4-98.  Removal of HARNESS ASSY MCU C/L
C A U T I O N
The claw on HARNESS ASSY MCU C/L is easily broken. Take 
care not to press it too much. 
Leg_Sec03_520EB
4)
6)-2
6)-2
6)-1
6)-1
7)-1
7)-2
5)