DISASSEMBLY AND ASSEMBLY
FUSER
392
4.9.3 HARNESS ASSY MCU C/L
REMOVAL
1.
2.
Remove COVER ASSY LH.
3.
Remove CHASSIS ASSY ESS.
4.
Disconnect the connector (black-and-white) from PWBA FUSER CONT.
5.
Disconnect connector (P417) from PWBA MCU.
6.
Remove the 2 screws (silver, with flange, 6 mm) fastening BRACKET-RIZ to the
main unit, remove the harness from the clamp, and remove BRACKET-RIZ from
the main unit.
main unit, remove the harness from the clamp, and remove BRACKET-RIZ from
the main unit.
7.
Draw out HARNESS ASSY MCU C/L from BRACKET-RIZ while pressing the
claw on HARNESS ASSY MCU C/L.
claw on HARNESS ASSY MCU C/L.
REINSTALLATION
1.
Insert the claw on HARNESS ASSY MCU C/L into the hole on BRACKET-RIZ
to attach.
to attach.
2.
Fasten BRACKET-RIZ to the main unit with the 2 screws (silver, with flange, 6
mm), and fasten each harness with the clamps.
mm), and fasten each harness with the clamps.
3.
Attach the harness (yellow) to the connector (P417) on PWBA MCU.
4.
Connect the harness (black-and-white) to PWBA FUSER CONT.
5.
Attach CHASSIS ASSY ESS.
6.
Attach COVER ASSY LH.
7.
Figure 4-98. Removal of HARNESS ASSY MCU C/L
C A U T I O N
The claw on HARNESS ASSY MCU C/L is easily broken. Take
care not to press it too much.
care not to press it too much.
Leg_Sec03_520EB
4)
6)-2
6)-2
6)-1
6)-1
7)-1
7)-2
5)