Calibrate
This feature is used to optimize the sensitivity of the Transmissive or 
Reflective sensors (whichever is selected in the Media Sensor sub-menu) in 
being able to detect the TOF (Top-of-Form) position of the current media 
installed. The sensitivity can be adjusted manually by changing the Refl Value 
or Trans Value menu settings or can be determined automatically by using 
the Run Calibrate procedure.
The change in values (derived automatically or manually entered) take affect 
immediately within the current configuration menu. They can be saved into 
non-volatile memory (menu’s 1-8 only) by using the Save Configuration 
procedure. We highly recommend that you take advantage of the Trans or 
Refl Values automatically determined by the Run Calibrate procedure before 
attempting to make any manual changes to the Values. If the Run Calibrate 
procedure fails to determine the proper values and ends with a fault message 
displayed (“GAP NOT DETECTED” or “LOAD PAPER”), you can manually 
enter the Refl Value or Trans Value and press the FEED key to determine if 
the gap or black stripe can be consistently detected.
Run Calibrate. Pressing the ENTER key with Run Calibrate displayed 
initializes the automatic calibration procedure. This advances the media a 
minimum of 11 inches plus the distance required to detect 3 additional 
TOF positions. The procedure is successfully completed if no fault 
message is displayed and the Sensed Distance value is correct. The 
result is that the Refl Value or Trans Value (depending on which media 
type is installed) and the Sensed Distance value will be determined 
automatically.
Refl Value. Value representing the sensitivity for distinguishing the 
difference between the black mark and label liner or tag stock for 
Reflective media. The value range is (0-20) and the default value is 10. 
This value can be determined automatically by using the Run Calibrate 
procedure or can be entered manually. Too high a value causes a “GAP 
NOT DETECTED” error message displayed, too low a value causes a 
“LOAD PAPER” error message. 
Trans Value. Value representing the sensitivity for distinguishing the 
difference between the label and the transmissive gap (hole, notch or 
label liner) for Transmissive media. The value range is (0-20) with a 
default of 10. This value can be determined automatically by using the 
Run Calibrate procedure or can be entered manually. Too high a value 
causes a “LOAD PAPER” error message displayed, too low a value 
causes a “GAP NOT DETECTED” message.
Sensed Distance. This value (in inches) represents the distance that 
was sensed between the TOF of one label to the TOF of the next label. 
With Transmissive media installed the distance equals the physical label 
length + one transmissive gap, notch or hole. With Reflective media 
installed the distance equals the trailing edge of one black mark to the 
trailing edge of the next. The factory default for Sensed Distance is 0.00 
inches. This value is automatically determined only after successful 
completion of the Run Calibrate procedure and cannot be changed 
manually.