Seiko TM-U590/U590P User Manual

Page of 54
Dip Switch Setting A-3
Parallel interface specification
Set 1
Set  2
Notes:
Changes in DIP switch settings (excluding switch 2-8 interface reset signal) are 
recognized only when the printer power is turned on or when the printer is 
reset by using the interface. If the DIP switch setting is changed after the 
printer power is turned on, the change does not take effect until the printer is 
turned on again or is reset.
If you turn on DIP switch 2-8 while the printer is turned on, the printer may be 
reset, depending on the signal state. DIP switches should not be changed 
while the printer power is on.
SW
Function
ON
OFF
1-1
Auto line feed
Always enabled
Always disabled
1-2
Receive buffer capacity
69 bytes
4K bytes
1-3 ~
1-8
Undefined
SW
Function
ON
OFF
2-1
Handshaking (BUSY 
condition)
•Receive buffer full
•Reading data
•Off-line
•Receive buffer full
•Reading data
2-2
Reserved
(Do not change settings)
Fixed to Off
2-3 ~
2-4
Undefined
2-5 ~
2-7
Reserved
(Do not change settings)
Fixed to Off
2-8
I/F pin 31 reset signal
(Do not change settings)
Fixed to On