Schlage SRP-275 User Manual

Page of 39
 
Rev. 1.01 
- 35 -
SRP-275
10-4  Electrical characteristics 
Item 
Description 
Remark 
Supply voltage 
24V DC  ±  10% 
 
Operating 
Mean : Approximately 0.5A 
Peak : Approximately 1.5A 
 
Current consumption 
(at 24V, except for drawer 
kick-out driving) 
Standby Mean: 
Approximately 
0.3A 
 
 
  NOTES 
Maximum 1A for drawer kick-out driving.
 
 
 
10-5  Reliability 
Item 
Description 
Remark 
Life firing frequency 
Mechanism : Approx. 10 million lines 
Auto cutter : Approx. 1 million cuts 
(End of life is defined as the point at which the printer 
reaches the beginning of the Wear out Period.) 
 
Head 
Approx. 300 million dots/wire 
 
 
 
10-6  Environment conditions 
Item 
Description 
Remark 
Temperature 
Operating : 0~50℃ (32~122℉) 
Storage : -10~50℃ (14~122℉) 
 
Relative humidity 
Operating : 10~90% RH (Non-condensing) 
Storage : 10~90% RH (Non-condensing)