Service Calibrations
 
5-11
HP DesignJet 5000 Series Printers Service Manual
2. Service Station Calibration
The purpose of this Service Calibration is to calibrate the Service 
Station in relation to the Carriage Assembly. The Service Station 
Calibration performs the following calibrations:
n
Line Sensor to Black Pen.
n
Drop Detector.
n
Primer.
Perform the Service Station Calibration whenever:
n
Carriage Assembly is disassembled or replaced.
n
Service Station is disassembled or replaced.
NOTE
If you get an error code, refer to Page 5-26, Calibration Error
Codes
 for its description and resolution.
Perform the Service Station Calibration as follows:
NOTE
To perform this Calibration, make sure you load white medium
that is the full width of the Printer.  
1. In the Service Calibrations submenu, scroll to "2.2 Service Station" 
and press Enter.
If the Media loaded is not the right size, the following message is 
displayed. Press Enter to exit.  Load the correct media and repeat 
the procedure.
PH
ON
E S
UPP
OR
T
2 Service Calibrations...
2.2 Service Station
2.1 Scan axis
2.3 ACCURACY
Top
Enter
Back

Press Enter
Make Selection
2.2 Service Station
 
Top
Enter
Back

Press ENTER to continue
Media too small.
Remove Media.
Press Enter