Zebra Technologies 105S User Manual

Page of 110
Zebra S-Series User’s Guide
61
8SSHU7UDQVPLVVLYH0HGLD6HQVRU3RVLWLRQ$GMXVWPHQW
To adjust the upper media sensor, refer to Figure 24 and follow these steps.
1. Remove the ribbon and locate the upper media sensor.
2. Loosen the Phillips head screw.
3. Slide the upper sensor along the slot to the desired position.  When 
using media that has a web between labels, position the media sensor 
anywhere along the web (if you have labels with rounded corners, do 
not position the sensor where the rounded corners of the label might be 
detected). When using tag stock, position the upper sensor directly 
over the hole or notch.
4. Tighten the Phillips head screw.
Note:   To adjust the upper section of the transmissive media sensor for 
the outside half of the media width, call a service technician.
Figure 24