1.9  Batteries 
1  Hardware Overview 
TECRA S1   Maintenance Manual 
1-19 
NOTE: The time required for normal charge depends on the power consumption by the 
system.  Using the fluorescent lamp and frequently accessing the disk consume much 
power and lengthen the charge time. 
Any of the following cases stops battery charge: 
1.  The battery becomes fully charged. 
2.  The AC adapter or battery pack is removed. 
3.  The battery or AC adapter voltage is abnormal. 
 Detection of full charge 
A full charge is detected only when the battery is being charged by quick or normal 
charge.  A full charge is detected when either of the following conditions is met: 
1.  The current in the battery charging circuit drops below the predetermined 
value. 
2.  The charging time exceeds the fixed limit. 
1.9.3 RTC 
Battery 
The RTC battery provides power to keep the current date, time and other system information 
in memory while the computer is turned off.  Table 1-8 lists the charging time and data 
preservation period of the RTC battery. 
Table 1-8  RTC battery charging/data preservation time 
Status Time 
Charging 
time 
AC Adapter or main battery pack used 
(power on) 
50 hours