GE BC5002 User Manual

Page of 50
 
 
8-2 
Intelligence Panel PC User’s Manual – August 2003 
GFK-2023C 
 
8
 
  
 
Expansion Cards 
The maximum power consumption of additional expansion cards should not exceed 20 
watts to avoid overheating. 
The IC5005/BC5005 and IC5008/BC5008 models support full length cards size (339 mm). 
The IC5002/BC5002 models support up to 290 mm cards size (3/4 ISA size).   
Dimensions 
 
IC5002/BC5002 
IC5005/BC5005 
IC5008/BC5008 
Dimensions  
(W x H x D): 
330 x 268 x 183 mm 
390 x 312 x 156 mm 
442 x 371 x 160 mm 
Mounting depth:  177 mm +  
50 mm for cooling top 
and bottom 
30 mm for cooling on 
sides 
150 mm +  
50 mm for cooling top 
and bottom 
30 mm for cooling on 
sides 
154 mm +  
50 mm for cooling top 
and bottom 
30 mm for cooling on 
sides 
Weight: 
6.9 Kg 
8.3 Kg 
10.7 Kg 
 
Environmental Specifications  
Temperature Operating: 
0—40°C 
Storage: -20—60°C 
Humidity 
Operating : 10—85% Non condensing 
Storage: 10—85% Non condensing 
Shock: 
Operating 15G equivalent, 11ms, 3 axis pos. and neg. 
Non-operating 30G Reference IEC 68-2-27. 
Vibration: 
Operating: 1G, 5 to 9 Hz; 1.0g 9 to 150 Hz. 
Non-operating: 2.5G, Reference IEC 68-2. 
Agency Approvals 
UL 1604 Class 1 Div 2 
CE 
Enclosure Protection 
NEMA 4 (IP 65) 
Noise Immunity 
(acc. To EN 50082-2) 
Electrostatic Discharge ESD EN 61000-4-2 
Radiated Electromagnetic RF Fields EN 61000-4-3, ENV 50204 
Fast transients BURST EN 61000-4-4 
Conducted Electromagnetic RF-Fields EN 61000-4-6, ENV 50141 
Emission 
(acc. To EN50081-2) 
RF voltage EN 55011, EN 55022 
RF fields EN 55011, EN 55022 
 
Standards 
■  The IC500x product models meet the test requirements for the CE mark under 
European test standards EN 55022 and EN 50082-2 
■  The IC500x meets the test requirements of  DIN EN 60950 (VDE0805. IEC950) 
"Safety of information processing equipment "