Emerson GXT 10KVA User Manual
![Emerson](https://files.manualsbrain.com/attachments/1ef3aaad462e024fde6cecf537a4c6c781334d44/common/fit/150/50/6dab323528eefa0342baa74a10c15551c3b956250cf9d62f2117dcdf42a7/brand_logo.jpeg)
Cable Installation
17
Figure 10 Electrical connections—non-transformer model MBC
120V
120V
208V
240V
Common Ground
Wire Connection Torque
Value: 13 in-lbs
Common Ground
Wire Connection Torque
Value: 120 in-lbs
Common Ground
Wire Connection Torque
Value: 120 in-lbs
Common Ground
Wire Connection
Torque Value: 120 in-lbs
TB4 UPS Output Terminal
Block
Wire Connection Torque
Value: 28 in-lbs
TB3 UPS Input Terminal
Block
Wire Connection Torque
Value: 28 in-lbs
TB5 Hardwire Output Terminal
Block
Wire Connection Torque
Value: 35 in-lbs
Wire Connection Torque
Wire Connection Torque
Value: 120 in-lbs
TB2 Maintenance Bypass
Terminal Block
Wire Connection Torque
Value: 50 in-lbs
TB1 Maintenance Bypass Terminal
Block
Wire Connection Torque
Value: 50 in-lbs