2.3    External Electrical Connection Interface 
2.3.1    Connection Of Input Cables 
The AC input terminals, SPD, rectifier AC input switch, PE bus and PE terminals 
are illustrated in Figure 1-6. SPD is just adjacent to the AC input terminals and has 
been connected in before delivery. PE bus is at the top of the MFU and is 
connected to the DC Power Cabinet through screws. PE bus is connected PE 
terminal through a cable. 
Connection requirements 
The AC mains is connected to the AC input terminals directly. There are 6 AC input 
modes as shown in Table 2-2: 
Table 2-2    AC input modes 
Item 
Function unit 
Amount 
3P+N/380V AC input   
 
1P+N /220V AC input   
 
L1+L2/220V AC input 
 
3P/220V AC input   
 
Terminals only - for individual rectifier AC feeds 
 
AC distribution 
2P MCB only - for individual rectifier AC feeds 
 
 
Connection method 
Strip the insulation layer of one end of the AC input cable, and then mounted the 
cable end with an H terminal. 
The cable mounted with an H terminal is shown in Figure 2-4. 
H Terminal
AC Input Cable
 
Figure 2-4    Cable mounted with H terminal 
After attaching the H terminal to the AC input cable, connect the AC input cable to 
the AC input terminals as shown in Figure 2-5: