CyberPower Systems 400E-GP Leaflet

Page of 2
 
5. 
USB Port to PC 
This port allows connection and   
communication from the USB port   
on the computer to the UPS unit. The   
UPS communicates its status to the   
PowerPanel
®
 Personal Edition   
software. This interface is also   
compatible with the UPS service   
provided by Windows 98, Windows   
ME, Windows NT, Windows 2000,   
Windows XP, Windows Server   
2003. 
 
NOTE: Only one of these two ports   
can be used as communication and   
control of the UPS unit at one time. 
 
 Functional Test
 
 
AC Mode 
The UPS delivers power to the loads derived from the utility and maintains proper battery charge. It also 
regulates the output voltage to within a narrow range. 
 
On-Battery Mode 
The UPS operates on battery when the line voltage or frequency has fallen outside the limits. Local 
users are alerted to this mode of operation by visual and audible indicators. The UPS provides power to 
the load from the battery and through its inverter and the output voltage and frequency of the UPS are 
regulated within a narrow range 
 
1. Switch 
On 
Press the power switch on the front panel then the green LED will light up.   
 
2. Switch 
Off 
Press again the power switch, the LED on the front panel will go off.   
 
3. 
Cold Start / Start on Battery:   
          This UPS can be turned on even when AC is not present.   
Press the power switch on the front panel then the green LED will light up and flashing.   
 
ROUTINE MAINTENANCE AND STORAGE 
 
ROUTINE MAINTENANCE
 
1. 
Use dry soft clothes to clean the front panel and plastic parts. Do not use any detergent that 
contains alcoholic ingredient.   
 
2. 
The expected lifetime of the battery is around 3 years. Improper operation and harsh environment 
will reduce the actual lifetime. 
 
3. 
Unplug the UPS from power inlet if the UPS will not operate for long period of time. 
 
STORAGE
 
1. 
First turn off your UPS and disconnect its power cord from the wall outlet. Disconnect all cables 
connected the UPS to avoid battery drain.   
 
2. 
The UPS should be stored in a cool dry location. 
 
3. 
Make sure the battery is fully charged before the UPS is stored. 
 
4. 
For extended storage in moderate climates, the battery should be charged for 12 hours every 3 
months by plugging the power cord into the wall receptacle and turning on the main switch. Repeat 
it every 2 months in high temperature locations. 
 
 
 
TROUBLE SHOOTING
 
 
Problem 
Possible Cause 
Solution 
Batteries are not fully 
charged. 
Recharge the battery by leaving the UPS 
plugged in. 
The UPS does 
not perform 
expected 
runtime. 
Battery is slightly worn out. 
Contact CyberPower Systems at 
service@cyberpower-eu.com
The on/off switch is 
designed to prevent 
damage by rapidly turning it 
off and on.   
Turn the UPS off. Wait 10 seconds and 
then turn the UPS on.   
The unit is not connected to 
an AC outlet. 
The unit must be connected to a 
220-240V 50/60Hz outlet.     
The battery is worn out. 
Contact CyberPower Systems at 
service@cyberpower-eu.com
The UPS will not 
turn on. 
 
Mechanical problem. 
Contact CyberPower Systems at 
service@cyberpower-eu.com
Fuse is blown due to 
overload 
Turn the UPS off and unplug at least one 
piece connected equipment. Unplug the 
power cord of the UPS then remove the 
fuse compartment beneath the power inlet 
of the UPS and replace the blown fuse 
with a spare one. Lock the compartment 
back to the UPS. Connect power cord 
then turn the UPS on. Make sure that your 
spare fuse meets the specification. 
Batteries are discharged 
Allow the unit to recharge for at least 4 
hours. 
Outlets do not 
provide power to 
equipment 
Unit has been damaged by 
a surge or spike. 
Contact CyberPower Systems at 
service@cyberpower-eu.com
The serial/USB cable is not 
connected. 
Connect the serial/USB cable to the UPS 
unit and an open serial port on the back 
of the computer. You must use the cable 
that came with the unit. 
PowerPanel
®
 
Personal Edition 
is inactive (all 
icons are gray). 
The serial/USB cable is 
connected to the wrong 
port. 
Try another serial/USB port of your 
computer. 
The unit is not providing 
battery power. 
Shutdown your computer and turn the 
UPS off. Wait 10 seconds and turn the 
UPS back on. This should reset the unit. 
The serial cable is not the 
cable that was provided with 
the unit. 
You must use the cable included with the 
unit for the software. 
 
 
TECHNICAL SPECIFICATIONS 
 
Model   
Value 400E-GP 
Value 600E-GP 
Value 800E-GP 
Capacity  (VA) 
400VA 
600VA 
800VA 
Capacity  (Watts) 
240W 
360W 
480W 
Input  
 
 
 
Input Voltage Range 
165-270Vac   
Frequency Range 
45~65 Hz (Auto Sensing) 
Output  
 
 
 
On Battery Output 
Voltage 
Simulated Sine Wave at 230Vac +/-10% 
On Battery Output 
Frequency  
50/60 Hz +/-1% 
Overload Protection 
On Utility: Fuse, On Battery: Internal Current Limiting 
Physical 
 
 
 
 
Total # of UPS 
Receptacles 
(3) IEC 320 C13 
Maximum Dimensions 
32cm(L)*10cm(W)*14cm(H) 
Weight   
4.2 Kgs / 9.3 Lbs 
5.3 Kgs / 11.7 Lbs
6.1 Kgs / 13.4 Lbs   
Battery 
 
 
 
 
Sealed Maintenance 
Free Lead Acid Battery
12V / 4.5Ah x1 
12V / 7Ah x1 
12V /
 9
Ah x1 
Typical Recharge Time
8 Hours 
Warning Diagnostics 
Indicators 
Power On / Using Battery 
Audible Alarms 
On Battery, Low Battery, Overload 
Environmental 
 
 
 
 
Operating Temperature
+32
°F to 95°F ( 0°C to 35°C ) 
Operating Relative 
Humidity 
0 to 95% NON-CONDENSING 
Communication 
 
 
 
 
PowerPanel
®
 
 
Personal Edition 
Software 
 
Windows2000/NT/XP/Server 2003/Vista,Mac OS, Linux 
Management 
 
 
 
 
Auto-Charger Yes 
Auto-Restart Yes 
USB Yes 
Other Features 
Green Power 
Yes (Energy saving technology) 
 
 
DEFINITIONS FOR ILLUMINATED LED INDICATORS 
 
 
       
       
 
LED 
 
 
 
 
 
Alarm 
 
 
 
Fuse 
 
Condition 
On Off 
Normal 
Normal 
Flash 
Two 
Beeps 
Normal 
Utility Failure - The UPS is providing battery power to outlets. 
Flash 
Rapid 
Beeps 
Normal 
Utility Failure - The UPS is providing battery power.    The 
rapid beeps indicate the battery will run out of power shortly. 
On/Flash 
Long 
Beep 
Normal/ 
Blown 
Overload - Occurs when connected equipment exceeds the 
rating of the unit. Turn the UPS off and unplug at least one 
piece of equipment from the UPS. Check the fuse and do the 
replacement if necessary. Turn the UPS on. 
 
For more information, visit eu.cyberpowersystems.com or contact 
CyberPower Systems B.V. 
Flight Forum 3545 5657DW Eindhoven The Netherlands 
Tel: +31 40 2348170, E-MAIL: sales@cyberpower-eu.com   
CyberPower Systems Inc. (USA) 4241 12th Avenue East Suite 400 Shakopee, MN 55379, U.S.A. 
Tel: +1 952 4039500, Fax: +1 952 4030009, E-MAIL: sales@cyberpowersystems.com   
Entire contents copyright ©2004 CyberPower Systems B.V., All rights reserved. Reproduction in whole 
or in part without permission is prohibited. PowerPanel
®
 and PowerPanel
®
 Plus are trademarks of 
CyberPower Systems (USA) Inc. 
 
 
 
 
 
 
CyberPower warrants to you, the original purchaser, that CyberPower UPS will be free from defects in 
design, assembly, materials and workmanship for two years ( battery is only one year) from the date of 
original purchase.  Any warranty services, please contact your local dealers or distributors.