MGE UPS Systems EX 7 RT 3:1 User Manual

Page of 38
 
34007724EN/AA
 - Page 23
Frequency converter
1 - Remove the terminal block cover
(5 screws),
2 - Remove the bridge connected between
L2 and L1,
3 - Insert the Normal AC cable through the
cable gland,
4 - Connect the 5 wires to the Normal AC
terminal block,
Always connect the earthing
wire first.
5 - Insert the Output cable suppling the load
through the Output cable gland,
6 - Connect the 3 wires to output terminal
block,
Do not connect anything to the
Bypass AC terminal block,
7 - Refit the terminal block cover and tighten
the cable glands,
8 - Secure the junction Input/Output box to
the rear of the power module by means of
the 3 screws.
1
5
3
6
4
7
2
1
1
1
7
7