MGE UPS Systems 250A User Manual
34020201EN/AB
- Page 7
A-01
A-03
A-05
A-07
A-09
A-11
A-13
A-15
A-17
A-19
I 0
I 0
I 0
I 0
I 0
I 0
Q1
Q2
B-01
B-03
B-05
B-07
B-09
B-11
B-13
B-15
B-17
B-19
C-01
C-03
C-05
C-07
C-09
C-11
C-13
C-15
C-17
C-19
A-02
A-04
A-06
A-08
A-10
A-12
A-14
A-16
A-18
A-20
B-02
B-04
B-06
B-08
B-10
B-12
B-14
B-16
B-18
B-20
C-02
C-04
C-06
C-08
C-10
C-12
C-14
C-16
C-18
C-20
I
0
I
0
A-01
A-03
A-05
A-07
A-09
A-11
A-13
A-15
A-17
A-19
A-21
A-23
A-25
A-27
A-29
A-31
A-33
A-35
A-37
A-39
A-41
A-03
A-05
A-07
A-09
A-11
A-13
A-15
A-17
A-19
A-21
A-23
A-25
A-27
A-29
A-31
A-33
A-35
A-37
A-39
A-41
I 0
B-01
B-03
B-05
B-07
B-09
B-11
B-13
B-15
B-17
B-19
B-21
B-23
B-25
B-27
B-29
B-31
B-33
B-35
B-37
B-39
B-41
B-03
B-05
B-07
B-09
B-11
B-13
B-15
B-17
B-19
B-21
B-23
B-25
B-27
B-29
B-31
B-33
B-35
B-37
B-39
B-41
I 0
C-01
C-03
C-05
C-07
C-09
C-11
C-13
C-15
C-17
C-19
C-21
C-23
C-25
C-27
C-29
C-31
C-33
C-35
C-37
C-39
C-41
C-03
C-05
C-07
C-09
C-11
C-13
C-15
C-17
C-19
C-21
C-23
C-25
C-27
C-29
C-31
C-33
C-35
C-37
C-39
C-41
I 0
A-02
A-04
A-06
A-08
A-10
A-12
A-14
A-16
A-18
A-20
A-22
A-24
A-26
A-28
A-30
A-32
A-34
A-36
A-38
A-40
A-42
A-04
A-06
A-08
A-10
A-12
A-14
A-16
A-18
A-20
A-22
A-24
A-26
A-28
A-30
A-32
A-34
A-36
A-38
A-40
A-42
I 0
B-02
B-04
B-06
B-08
B-10
B-12
B-14
B-16
B-18
B-20
B-22
B-24
B-26
B-28
B-30
B-32
B-34
B-36
B-38
B-40
B-42
B-04
B-06
B-08
B-10
B-12
B-14
B-16
B-18
B-20
B-22
B-24
B-26
B-28
B-30
B-32
B-34
B-36
B-38
B-40
B-42
I 0
C-02
C-04
C-06
C-08
C-10
C-12
C-14
C-16
C-18
C-20
C-22
C-24
C-26
C-28
C-30
C-32
C-34
C-36
C-38
C-40
C-42
C-04
C-06
C-08
C-10
C-12
C-14
C-16
C-18
C-20
C-22
C-24
C-26
C-28
C-30
C-32
C-34
C-36
C-38
C-40
C-42
I 0
Q1
Q2
I
0
I
0
1. Presentation
1.2 Access to the circuit breakers
Version with 126 circuit breakers (doors open)
Version with 60 circuit breakers (doors open)
2
6
7
8
4
5
F1 disconnector-fuse for protection of the
control electronics
control electronics
Upstream general protection circuit breaker
(only in modules with an isolation
transformer)
(only in modules with an isolation
transformer)
General protection circuit breaker for the 126
output circuits
output circuits
2 x 21 circuit breakers for phase A (A-1 to A-
41 and A-2 to A-42)
41 and A-2 to A-42)
2 x 21 circuit breakers for phase B (B-1 to B-
41 and B-2 to B-42)
41 and B-2 to B-42)
2 x 21 circuit breakers for phase C (C-1 to
C-41 and C-2 to C-42)
C-41 and C-2 to C-42)
4
5
Upstream general protection circuit breaker
(only in modules with an isolation
transformer)
(only in modules with an isolation
transformer)
General protection circuit breaker for the 60
output circuits
output circuits
F2 disconnector-fuse for protection of the
voltage measurement inputs
voltage measurement inputs
3
F1 disconnector-fuse for protection of the
control electronics
control electronics
2 x 10 circuit breakers with earth-leakage
protection for phase A (A-1 to A-19 and A-2
to A-20)
2 x 10 circuit breakers with earth-leakage
protection for phase B (B-1 to B-19 and B-2
to B-20)
2 x 10 circuit breakers with earth-leakage
protection for phase C (C-1 to C-19 and C-2
to C-20)
protection for phase A (A-1 to A-19 and A-2
to A-20)
2 x 10 circuit breakers with earth-leakage
protection for phase B (B-1 to B-19 and B-2
to B-20)
2 x 10 circuit breakers with earth-leakage
protection for phase C (C-1 to C-19 and C-2
to C-20)
F2 disconnector-fuse for protection of the
voltage measurement inputs
voltage measurement inputs
9
Eight connection cover panels
2
6
7
8
3
9
Eight connection cover panels