APC SMC1000 User Manual
Smart-UPS C 1000/1500 VA 120/230 Vac Tower
5
Status Indicators
Display panel features
LED status indicators
1000/1500 VA 120 Vac
1000/1500 VA 230 Vac
1
On Line/On Battery LED
4
Display interface
2
P
OWER
O
N
/O
FF
button
5
D
ISPLAY
button
3
Site Wiring/System Fault LED
6
M
UTE
button
Note:
Refer to Feature Reference Guide on page 8 in this manual for a detailed description of
the front panel buttons and icons.
Status
LED
Audible
Indicator On
Audible Indicator Terminates
Power On
The UPS is supplying AC power to
connected equipment.
The UPS is supplying AC power to
connected equipment.
The On Line/On Battery LED
illuminates green.
illuminates green.
None
N/A
On Battery
The UPS is supplying battery power
from the internal battery.
The UPS is supplying battery power
from the internal battery.
The On Line/On Battery LED
illuminates amber.
illuminates amber.
The UPS beeps
4 times every 30
seconds.
4 times every 30
seconds.
The beeping stops when AC power
is restored or the M
is restored or the M
UTE
button is
pressed for 0.2 seconds.
System Fault
The UPS detects an internal system
fault.
The UPS detects an internal system
fault.
System Fault LED
illuminates red.
Constant tone
The alarm stops when the P
OWER
O
N
/O
FF
button is pressed for 2
seconds. This creates a Fault
Reset.
Reset.
Site Wiring Fault
A building wiring fault has occurred.
Do not operate the UPS. Contact a
qualified electrical person to correct the
building wiring fault.
A building wiring fault has occurred.
Do not operate the UPS. Contact a
qualified electrical person to correct the
building wiring fault.
Site Wiring Fault
LED flashes red.
LED flashes red.
None
N/A