APC BX1300G User Manual

Page of 10
Installation and Operation  Back-UPS BX1300G/BN1350G/BX1500G
6
Modes of operation
Press 
D
ISPLAY
 to scroll through the display screens.
Status indicators
System faults
On Line Mode
On Battery Mode
Input Voltage
Estimated runtime in minutes
Counter
Power Event Counter 
Estimated run time
Output Voltage 
Load in Watts 
Input Voltage 
Load in % 
Load in Watts
Output Voltage
Load in %
Output Frequency
Output Frequency
Status
LED 
Audible Alarms
Audible Alarm Terminates
Overload 
An overload condition has occurred 
while operating on AC or battery power.
Constant tone
The alarm stops when nonessential 
equipment is disconnected from the 
Battery Backup outlets or the Back-UPS 
is turned off.
On Battery
The Back-UPS is supplying battery 
power to the Battery Backup outlets.
Beeps 4 times every 30 
seconds.
The beeping stops when AC power is 
restored or the Back-UPS is turned off.
Low Battery
The Back-UPS is supplying battery 
power to the Battery Backup outlets and 
the battery is near a total discharge state.
Continuous beeping
The beeping stops when AC power is 
restored or the Back-UPS is turned off.
F01
On-Battery Overload
Turn the Back-UPS off. Disconnect non-essential 
equipment from the Battery Backup outlets and then 
turn Back-UPS on.
F02
On-Battery Output Short
Turn the Back-UPS off. Disconnect non-essential 
equipment from the Battery Backup outlets and then 
turn Back-UPS on.
F03
On-Battery Xcap Overload
Faults F03-F09 are not user serviceable. Contact APC 
Technical Support for assistance.
F04
Clamp Short
F05
Charge Fault
F06
Relay Welding
F07
Temperature
F08
Fan Fault
F09
Internal Fault