Troubleshooting
Problem
Possible Cause
Corrective Action
Back-UPS will not switch on.
The Back-UPS is not connected to utility 
power.
Ensure that the Back-UPS is securely connected 
to an AC outlet.
The circuit breaker has been tripped.
Disconnect non-essential equipment from the 
Back-UPS. Reset the circuit breaker. Re-connect 
equipment one item at a time. If the circuit 
breaker is tripped again, disconnect the device 
that caused the trip.
The internal battery is not connected.
Connect the battery.
The utility input voltage is out of range.
Adjust the transfer voltage and sensitivity range.
The Back-UPS does not 
provide power during a utility 
power outage.
Ensure that essential equipment is not 
plugged into a 
S
URGE
 O
NLY
 outlet.
Disconnect equipment from the 
S
URGE
 O
NLY
 
outlet and re-connect to a Battery Backup outlet.
The Back-UPS is operating on 
battery power, while connected 
to utility power.
The plug has partially pulled out of the wall 
outlet, the wall outlet is no longer receiving 
utility power, or the circuit breaker has been 
tripped.
Ensure that the plug is fully inserted into the 
wall outlet. Ensure that the wall outlet is 
receiving utility power by checking it with 
another device.
The Back-UPS is performing an automatic 
self test.
No action is necessary.
The utility input voltage is out of range, the 
frequency is out of range, or the waveform 
is distorted.
Adjust the transfer voltage and sensitivity range.
The Back-UPS does not 
provide the expected amount of 
backup time.
Battery Backup outlets may be fully or 
improperly loaded.
Disconnect non-essential equipment from the 
Battery Backup outlets and connect the 
equipment to 
S
URGE
 O
NLY
 outlets.
The battery was recently discharged due to a 
power outage and has not fully recharged.
Charge the battery cartridge for 16 hours.
The battery has reached the end of its useful 
life.
Replace the battery.
The
 R
EPLACE
 B
ATTERY
 
indicator is illuminated.
The battery has reached the end of its useful 
life.
Replace the battery.
The O
VERLOAD
 indicator is 
illuminated.
The equipment connected to the Back-UPS 
is drawing more power than the Back-UPS 
can provide.
Disconnect non-essential equipment from the 
Battery Backup outlets and connect the 
equipment to 
S
URGE
 O
NLY
 outlets.
The 
S
YSTEM
 F
AULT
 indicator is 
illuminated, all the front panel 
indicators are flashing.
There is an internal fault.
Determine which internal fault message is 
displayed by matching the number displayed on 
the LCD with the corresponding Fault Message 
(see System Faults) and contact APC Technical 
Support.
Power is not supplied to some 
outlets.
Power to the Controlled outlets has 
intentionally been turned off.
Confirm that the correct peripherals are 
connected to Controlled outlets. If this feature is 
not desired, disable the Power-Saving Master 
and Controlled outlets.
The Controlled outlets are not 
supplying power, even though 
the Master device is not in sleep 
mode.
The Master Outlet threshold may be 
incorrectly set.
Adjust the threshold when the Master outlet 
signals the Controlled outlets to shut down.