Anton/Bauer HyTron 100 User Manual

Page of 19
 
 
 
 
 
 
 -The large numbers 1, 2 or 3 indicate 
remaining hours under current load 
(only one number will display at any 
one time) 
 -The pie chart numbers (15, 30, 45, or 
60) 
indicate remaining minutes under 
current load.   
 -The InterActive Segment indicates a 
FULLY CHARGED battery verified 
by charger communication 
-Top BAR:  Indicates 75%-96% 
- 2
nd
 BAR:  Indicates 50% - 75% 
- 3
Rd
 BAR:  Indicates 25% - 50% 
- 4
th
 BAR:  Indicates 7% - 25% 
- INTERACTIVE 96 - 100% 
-RES BAR:  Indicates 0 - 6% 
1. 
“INTERACTIVE” SEGMENT:  When illuminated, it indicates the 
HyTRON battery has completed its full charge routine. 
2. 
“RES” Bar:  Is the last “Fuel Gauge” Bar and will start to flash at 
6% capacity and will continue to flash until EOD is reached.
 
3. 
“SERVICE” SEGMENT:  Indicates self-diagnostic functions have 
detected anomalies. A battery with a “Service” flag should be returned 
to the Anton/Bauer Service Department.
 
4. 
“SIDE BAR” SEGMENTS:  Will remain ON (see below).