APC 15000 RAID User Manual

Page of 152
Drive Enclosure Installation
007-5510-002
 113
6.5 SAS DEM
The drive enclosure contains eight (8) top-loadable DEMs. The DEMs provide the SAS connectivity 
between the I/O module and the HDDs located within the enclosure. Each DEM connects to a single port 
of the HDD based on the location within the enclosure in which it is installed. Each of the eight DEMs 
installed in the enclosure has a unique I
2
C and SAS address based on a proprietary SAS address 
generation scheme.
6.6 SATA Interposer Features
The drive enclosure supports an active/active SATA MUX interposer which allows simultaneous access 
to the SATA HDD from both I/O modules installed in the enclosure. The MUX is implemented as a 
dongle module installed in the HDD carrier assembly. Additionally, the SATA interposer allows the 
power cycling of an individual HDD via SES commands.
6.7 Drive Enclosure Device Addressing
See Appendix B, “Drive Addressing”.
6.8 Grounding Checks
The product must only be connected to a power source that has a safety electrical earth connection.
Warning
If more than one product is fitted in a rack, the earth connection to the rack is even more 
important, because the rack will then have a high “EARTH LEAKAGE CURRENT” (“TOUCH 
CURRENT”).
The earth connection to the rack must be checked before switching on, by an electrical engineer who is 
qualified to the appropriate local and National standards to perform the check.