Drive Enclosure Troubleshooting
007-5510-002
 121
8.4 Audible Alarm
When the Audible Alarm sounds, use the appropriate SES CLI command. 
8.4.1
Top Cover Open  
The Audible Alarm sounds anytime the top cover is open. The alarm mutes automatically once the cover 
is closed.
8.4.2
SES Command  
The Audible Alarm can be set through  SES communication. When set in this manner, the alarm remains 
on until any one of the following conditions is met:
• Enclosure is power cycled.
• Alarm is turned off through SES command.
8.5 Troubleshooting
The following sections describe common problems (and possible solutions) you might encounter with 
your drive enclosure system.
8.5.1
Thermal Control
The drive enclosure uses extensive thermal monitoring and takes a number of actions to ensure 
component temperatures are kept low and also to minimize acoustic noise. Air flow is from the front, 
over the drive section, through the midplane, through the I/O modules to rear of the enclosure.
Cover Open 
AMBER
Enclosure cover 
is open
OFF-both cover pieces securely 
closed and latched in place.
ON-either of the cover pieces is 
NOT securely closed and 
latched in place
DEM Fault
AMBER
DEM fault
OFF-all DEMs operating 
correctly.
ON-at least one DEM has failed; 
service action required
Drive Fault
AMBER
Drive fault
ON-one or more HDDs are 
faulted. SES must determine 
exact HDD.
OFF-no detectable drive faults
Table 8–5
 Display Panel LEDs
ICON
LABEL
COLOR
Definition
Normal Behavior