APC 15000 RAID User Manual

Page of 152
Introduction
007-5510-002
  9
1.2.3
Uninterruptible Power Supply (UPS) 
Using an Uninterruptible Power Supply (UPS) with the controller is highly recommended. The UPS can 
guarantee power to the system in the event of a power failure for a short time, which will allow the system 
to power down properly. 
SGI offers two types of UPS: basic and redundant. The basic UPS  is rack-mountable. It can maintain 
power to a five (5) enclosure system for seven (7) minutes while the system safely shuts down during a 
power failure. The redundant UPS contains power cells that provide a redundant UPS solution. 
NOTE : The UPS should be installed by a licensed electrician.  Contact SGI to obtain circuit and 
power requirements. 
Status Indicator
Led Activity
Explanation
Disk
Solid Green
All related disk enclosures are operating 
normally
Solid Amber
There is a problem with 1 or more of the disk 
enclosures
Temp Status
Solid Green
All temp sensors operating normally
Solid Amber
At least 1 temp sensor has reported over-
temperature conditions
Solid Red
2 or more temp sensors has reported over-
temperature condition
DC
Solid Green
Operating normally
Solid Amber
Non-critical power supply fault
Solid Red
Critical power supply fault
Fan Status
Solid Green
Operating normally
Flashing Green
System monitoring activity
Flashing Amber
1 fan has failed and needs to be replaced
Solid Red
2 or more fans have failed or are undetected and 
the system will shutdown in 30 seconds
AC Fail
Solid Green
Operating normally
Solid Red
Power input to supply not present. AC failure
FC (FC-8 only)
Solid
Physical connection has been made.
Flashing
Data is being transferred.
Table 1–1
LED Indicators