APC 15000 RAID User Manual

Page of 152
Controller Installation
26 
007-5510-002
10. Enter a new unique LUN mapping for this user. Options are shown in Table 2–2 on page 26.
11. Connect user 2 and repeat steps 2--10 to specify the host port zoning and LUN mappings with the 
following changes: 
- For active host port (step 6), enter port 2 only. 
- For LUN mapping: 
External LUN 0 is mapping to internal LUN: R1
 
External LUN 1 is mapping to internal LUN: 1
External LUN 2 is mapping to internal LUN: q
 
NOTE : In this scheme, users 1 and 2 have their own custom LUN identification scheme. The internal 
LUN 1 that is shared by the users needs to be managed by SAN management software. 
The individual dedicated LUN appears to the user as local storage and does not require 
external management software. 
12. To display the new security settings, type: 
user
<Enter>
Figure 2–12 shows a finished sample.
Figure 2–12
Security Settings Screen
Table 2–2
LUN Mapping Options.
Option
Description
G.1
GROUP.LUN number
P
place-holder
R
Read-Only. Place before the GROUP.LUN
N
Clear current assignment
<cr>
No Change
E
EXIT
?
Display detailed help text.
15000 [1]: user
LUN Zoning
-------------------------------------------------------------------------------
User
210000E08B057383
000 client1
World Wide Name
1  4
User auditing is enabled.
External LUN, Internal LUN
Ports
1
2
 R000,001 
001,0
210000E08B028233
128 client2
 2 
 
R000,001 001,1