TP-LINK tl-sl5428e Data Sheet

Page of 303
 
Threshold: 
Specify the threshold for the selected link event.   
 
For Symbol Period Error, it is the number of error symbols in 
the period that is required to be exceeded. 
 
For Frame Error, it is the number of error frames in the period 
(measured by 100ms) that is required to be exceeded. 
 
For Frame Period Error, it is the number of error frames in the 
period (measured by frames) that is required to be exceeded.
 
For Frame Seconds Error, it is the number of error frame 
seconds in the period that is required to be exceeded. 
Window: 
Specify the detection period. 
 
For Frame Period Error, the period is specified by a number of 
received frames. 
 
For other link events, the period is specified by a time interval.
Notify: 
Choose whether to notify the selected link event or not. 
8.3  RFI 
On this page, you can choose whether to notify the link faults like dying gasp and critical event. 
Choose the menu Ethernet OAM→RFI→Remote Failure Indication to load the following page. 
 
Figure 8-7 Remote Failure Indication 
The following entries are displayed on this screen:
 
 
Remote Failure Indication Config 
Port Select: 
Click the Select  button to quick-select the corresponding port 
based on the port number you entered. 
121