Cabletron Systems CSX1000 User Manual

Page of 644
USER’S GUIDE
248      CyberSWITCH
C
ONFIGURING
 E
XCEPTION
 F
ILTER
The IP Exception Filter is intended for temporary, special conditions within an existing forwarding 
filter. When enabled, it is logically appended to the beginning of each forwarding filter in effect.
U
SING
 CFGEDIT
1.
Select Exception Filter from the IP Filter menu.
2.
Enable the Exception Filter. (By default, the Exception Filter is disabled.)
3.
Select Edit the Exception Filter. A screen similar to the following will be displayed:
4.
Select Add to add a condition.
5.
Enter the name of the packet type to be forwarded. A screen similar to the following is then 
displayed:
6.
If the filter already has a forwarding condition (other than the final condition), an additional prompt 
is presented concerning the condition’s position within the filter. Enter the location within the 
filter where the condition is to be added:
at the beginning
at the end
after the existing condition with id number “n”.
Note:
If the Final Condition of the filter needs modification, do so via the Change Default Condition 
selection on the Conditions for Filter menu. In this screen context, default condition refers to 
final condition.
Conditions for "Except_Filter"
Final Condition
DISCARD
All Other Types
(1) Add,    (2) Change,    (3) Delete,    (4) Move a CONDITION, 
(5) Change Default Condition   or press <RET> for previous menu: 
Conditions for "Except_Filter"
Final Condition
DISCARD
All Other Types
(1) Add,    (2) Change,    (3) Delete,    (4) Move a CONDITION, 
(5) Change Default Condition   or press <RET> for previous menu: 
Conditions for "Except_Filter"
id
1
FORWARD
"Type_Two"
Final Condition
DISCARD
All Other Types
(1) Add,    (2) Change,    (3) Delete,    (4) Move a CONDITION, 
(5) Change Default Condition   or press <RET> for previous menu: