Cabletron Systems ZX-250 User Manual

Page of 132
SmartCell ZX-250 User Guide   4-11
Switch Administration
PVC Connections  
Use the 
show alarms
 command to view a list of the currently logged alarms. For example, 
SmartCell ZX # show alarms
Index(ALL)                                :
0  000:00:31:164
---------------------------------------------------
LECS Operational
---------------------------------------------------
Failed to re-establish SAAL connection
Port ID 0x0000000b
T309    10000
1  043:15:56:718
---------------------------------------------------
Failed to re-establish SAAL connection
Port ID 0x0000000b
T309    10000
2  043:29:55:392
More(<space>/q)?:
Alarms are displayed in the following format:
U
Alarm number — The index number of the alarm in the circular buffer
U
Alarm ID — Unique ID assigned to the alarm
U
Time — Time of alarm, in switch up-time in hours, minutes, seconds, and milliseconds
U
Object — The object affected by the alarm (port, LEC, and so on)
U
Description — Brief message describing the alarm
Alarm messages can be automatically displayed on the SmartCell ZX-250 console. Use the 
set AlarmDisplay
 
command to display alarms on the console as they occur:
SmartCell ZX # set alarmdisplay
alarmDisplay(OFF)                         : on
SmartCell ZX #
4.4.3
Deleting Events and Alarms
To delete events or alarms currently logged within your SmartCell ZX-250, use the 
delete events
 and 
delete alarms
 
commands, respectively.
4.5
PVC CONNECTIONS
The SmartCell ZX-250 supports Permanent Virtual Circuits (PVCs), both point-to-point and point-to-multipoint. Use 
PVCs to connect devices (that do not support SVCs) to a switch’s local client. Also, use PVCs to make connections 
through the SmartCell ZX-250 between devices that support only PVCs.
Use point-to-point PVCs to connect one end node to another for two-way communication. Use point-to-multipoint 
PVCs to connect a broadcast end node to a group of receiving end nodes; traffic is one way.
2p›F
PVCs use traffic descriptors to define their traffic characteristics. If you are 
unfamiliar with traffic descriptors, see Section 4.6.1, “Traffic Descriptors.”