Lantronix 900-510 User Manual

Page of 280
8: Device Ports 
SLB™ Branch Office Manager User Guide 
 
90 
Modem Settings: PPP Mode 
Negotiate IP 
Address 
If the SLB branch office manager and/or the serial device 
have dynamic IP addresses (e.g., IP addresses assigned 
by a DHCP server), select YesYes is the default. 
If the SLB branch office manager or the modem have fixed 
IP addresses, select No, and enter the local IP (IP address 
of the port) and remote IP (IP address of the modem).  
Authentication 
Enables PAP or CHAP authentication for modem logins. 
PAP is the default. With PAP, users are authenticated by 
means of the Local Users and any of the remote 
authentication methods that are enabled. With CHAP, the 
CHAP Handshake fields authenticate the user. 
CHAP Handshake 
The host/username (for UNIX systems) or secret/user 
password (for Windows systems) used for CHAP 
authentication. May have up to 128 characters. 
Same 
authentication for 
Dial-in & Dial-on-
Demand (DOD) 
Select this option to let incoming connections (dial-in) use 
the same authentication settings as outgoing connections 
(dial-on-demand). If this option is not selected, then the 
dial-on-demand connections take their authentication 
settings from the DOD parameter settings. If DOD 
Authentication is PAP, then the DOD CHAP Handshake 
field is not used.  
DOD 
Authentication 
Enables PAP or CHAP authentication for dial-in & dial-on-
demand. PAP is the default. With PAP, users are 
authenticated by means of the Local Users and any of the 
remote authentication methods that are enabled. With 
CHAP, the DOD CHAP Handshake fields authenticate the 
user. 
DOD CHAP 
Handshake 
For DOD Authentication, enter the host/username for 
UNIX systems) or secret/user password (for Windows 
systems) used for CHAP authentication. May have up to 
128 characters. 
Enable NAT 
Select to enable Network Address Translation (NAT) for 
dial-in and dial-out PPP connections on a per modem 
(device port or PC Card) basis. Users dialing into the SLB 
branch office manager access the network connected to 
Eth1 and/or Eth2. 
Note:
 IP forwarding must be enabled on the  
Network - Settings page for NAT to work. See
 
Dial-out 
Number 
Phone number for dialing out to a remote system or serial 
device. May have up to 20 characters. Any format is 
acceptable. 
Dial-out 
Login 
User ID for dialing out to a remote system. May have up to 
32 characters. 
Dial-out Password 
and Retype 
Password for dialing out to a remote system. May have up 
to 64 characters.