6 Rear 
Panel 
Kingston Technology Company                  KND2410TX User’s Guide - Rev. A01 
Rear Panel 
 
Fig. 1-3  Rear Panel 
Power Switch 
The AC Power switch turns the unit ON or OFF.  If the PWR LED does not light up 
once the unit has been turned on, try the procedures below (in the following order): 
 
1. 
Try a different AC power outlet. 
2.  Check the external fuse located at the back of unit (below the AC 
power connector).  If the fuse is blown, replace it with the spare fuse 
provided with the unit.  (See Fuse Compartment display on page 8) 
3. 
The power supply may be defective. Return the unit for replacement. 
WARNING: For safety reasons, DO NOT attempt to open and 
service the unit.  There are no user-serviceable components 
inside. 
AC Power Connector 
The Fast EtheRx dual-speed hubs use 100-240VAC internal power supplies.  
Connect the AC power cord from the back of the unit to an AC electrical outlet. 
Fuse 
The Fast EtheRx dual-speed hubs come equipped with one external fuse and one 
spare fuse.  Both fuses are in a fuse holder located just below the AC power 
connector on the back of the unit.  Both fuses are rated 250V/2A max. 
Fan Unit(s) 
The Fast EtheRx dual-speed hubs use independent cooling fans for optimum air-
flow to safeguard the unit from unnecessary heat exposure. 
 
F u s e   ( 2 5 0 V,   2 A )
U S E   O N L Y   W I T H   A   2 5 0 V   F U S E
Dip Switches
Stack-In / Stack-Out
         Ports
Fan
Power Switch
AC Power
Connector