Kingston Technology KND2415TX User Manual

Page of 25
Kingston Technology Company
KND2415TX User’s Guide - Rev. A00
16
Appendix D   Commonly Asked Questions
What are the Guidelines for Proper Termination?
It is important to maintain the twists of the cable as close to the termination on the outlet 
as  possible,  to  avoid  NEXT  (Near  End  Cross  Talk)  and  to  maintain  the  transmissions 
characteristics  of  the  Category.  Category  specications  require  that  pair  twisting  be 
maintained to within the following distances from the outlet termination:
  •   Category 3
 
maximum allowed untwisting:
  3 inches
  •
  
Category 4 maximum allowed untwisting:  1 inch
  •   Category 5 maximum allowed untwisting:  1/2 inch
Can I mix CAT 3 and CAT 5 cabling in the same building?
Yes, but keep in mind, you will not have CAT 5 performance. It is a good idea to keep the 
lines separated when installing any new lines.  Use CAT 5 UTP cabling only.
Can  a  Four-Pair  CAT  5  cable  support  two  100BASE-TX 
devices?
Although  only  two  pairs  are  used  in  the  standard  four-pair  CAT  5  UTP  cable,  it  is  not 
recommended because it exceeds the specications outlined by IEEE 802.3u.