Kingston Technology KND810TX User Manual

Page of 25
Appendix B    Cabling Guidelines 
11 
KND2410TX User’s Guide - Rev. A01 
Kingston Technology Company 
Appendix B    Cabling Guidelines 
UTP Cable Type 
When installing network cables, the following table shows appropriate cabling 
guidelines for 100BASE-TX Fast Ethernet architecture. 
Cabling Components: 
100BASE-TX 
Trunk and Patch Cable 
Type: 
4-Pair 100
Ω UTP CAT 5 
(only 2 pairs used) 
Modular Plug: 
8-Pin RJ-45 CAT 5 only 
Patch Panel: 
8-Pin RJ-45 CAT 5 only 
Table B-1  Network Cable Guidelines 
(NOTE: All UTP cables come in both solid and stranded filament.  Solid 
filament cables are more rigid and usually intended for trunk cabling.  
Stranded filament cables are more pliable and generally targeted for patch 
cables.  For proper termination, use the correct RJ-45 connector, as they 
differ for each type of cable.) 
UTP Cable Wiring 
UTP cables are wired based on one of two standard pin configurations: 
Straight-Through and Cross-Over.  100BASE-TX uses only Category-5 UTP 
cables with four pairs of wire as illustrated below in Tables B-2 and B-3.   
 "Straight-Through" 
"Cross-Over” 
 Configuration 
Configuration 
 
Pin Number  Pin Number
 
Pin Number
Pin Number 
   1 (TRX+) 
   1 (TRX+) 
 
   1 (TRX+) 
   3 (RCV+) 
   2 (TRX-) 
   2 (TRX-) 
 
   2 (TRX-) 
   6 (RCV-) 
   3 (RCV+) 
   3 (RCV+) 
 
   3 (RCV+) 
   1 (TRX+) 
   6 (RCV-) 
   6 (RCV-) 
 
   6 (RCV-) 
   2 (TRX-) 
   4, 5, 7, 8 
   Not Used 
 
   4, 5, 7, 8 
   Not Used 
Table B-2.  Straight-Through Wiring           Table B-3.  Cross-Over Wiring 
UTP Cable Wiring Standards