Cisco Systems 3130 User Manual

Page of 1226
 
19-5
Cisco Catalyst Blade Switch 3130 for Dell Software Configuration Guide
OL-13270-01
Chapter 19      Configuring Optional Spanning-Tree Features
Understanding Optional Spanning-Tree Features
Figure 19-3
UplinkFast Example Before Direct Link Failure
If Switch C detects a link failure on the currently active link L2 on the root port (a direct link failure), 
UplinkFast unblocks the blocked interface on Switch C and transitions it to the forwarding state without 
going through the listening and learning states, as shown in 
. This change takes 
approximately 1 to 5 seconds.
Figure 19-4
UplinkFast Example After Direct Link Failure
Understanding Cross-Stack UplinkFast
The UplinkFast feature is the cross-stack UplinkFast feature. Cross-stack UplinkFast (CSUF) provides 
a fast spanning-tree transition (fast convergence in less than 1 second under normal network conditions) 
across a switch stack. During the fast transition, an alternate redundant link on the switch stack is placed 
in the forwarding state without causing temporary spanning-tree loops or loss of connectivity to the 
backbone. With this feature, you can have a redundant and resilient network in some configurations. 
CSUF is automatically enabled when you enable the UplinkFast feature by using the spanning-tree 
uplinkfast
 global configuration command.
CSUF might not provide a fast transition all the time; in these cases, the normal spanning-tree transition 
occurs, completing in 30 to 40 seconds. For more information, see the 
L1
L2
L3
Switch C
Switch A
(Root)
Switch B
Blocked port
43575
L1
L2
L3
Switch C
Switch A
(Root)
Switch B
UplinkFast transitions port
directly to forwarding state.
Link failure
43576