Understanding Optional Spanning-Tree Features
If link L1 fails as shown in 
, Switch C cannot detect this failure because it is not connected 
directly to link L1. However, because Switch B is directly connected to the root switch over L1, it detects 
the failure, elects itself the root, and begins sending BPDUs to Switch C, identifying itself as the root. 
When Switch C receives the inferior BPDUs from Switch B, Switch C assumes that an indirect failure 
has occurred. At that point, BackboneFast allows the blocked interface on Switch C to move 
immediately to the listening state without waiting for the maximum aging time for the interface to expire. 
BackboneFast then transitions the Layer 2 interface on Switch C to the forwarding state, providing a path 
from Switch B to Switch A. The root-switch election
 
takes approximately 30 seconds, twice the Forward 
Delay time if the default Forward Delay time of 15 seconds is set. 
 shows how BackboneFast 
reconfigures the topology to account for the failure of link L1.
Figure 19-7
BackboneFast Example After Indirect Link Failure
If a new switch is introduced into a shared-medium topology as shown in 
, BackboneFast is 
not activated because the inferior BPDUs did not come from the recognized designated switch 
(Switch B). The new switch begins sending inferior BPDUs that indicate it is the root switch. However, 
the other switches ignore these inferior BPDUs, and the new switch learns that Switch B is the 
designated switch to Switch A, the root switch. 
Figure 19-8
Adding a Switch in a Shared-Medium Topology
L1
L2
L3
Switch C
Switch A
(Root)
Switch B
Link failure
44964
BackboneFast changes port
through listening and learning 
states to forwarding state.
Switch A
(Root)
Switch C
Switch B
(Designated bridge)
Added switch
4
4965
Blocked port