Cisco Systems 3130 User Manual

Page of 1226
 
19-16
Cisco Catalyst Blade Switch 3130 for Dell Software Configuration Guide
OL-13270-01
Chapter 19      Configuring Optional Spanning-Tree Features
Configuring Optional Spanning-Tree Features
Beginning in privileged EXEC mode, follow these steps to enable UplinkFast and CSUF. This procedure 
is optional.
When UplinkFast is enabled, the switch priority of all VLANs is set to 49152. If you change the path 
cost to a value less than 3000 and you enable UplinkFast or UplinkFast is already enabled, the path cost 
of all interfaces and VLAN trunks is increased by 3000 (if you change the path cost to 3000 or above, 
the path cost is not altered). The changes to the switch priority and the path cost reduce the chance that 
a switch will become the root switch. 
When UplinkFast is disabled, the switch priorities of all VLANs and path costs of all interfaces are set 
to default values if you did not modify them from their defaults.
To return the update packet rate to the default setting, use the no spanning-tree uplinkfast 
max-update-rate
 global configuration command. To disable UplinkFast, use the no spanning-tree 
uplinkfast
 command.
Enabling Cross-Stack UplinkFast
When you enable or disable the UplinkFast feature by using the spanning-tree uplinkfast global 
configuration command, CSUF is automatically globally enabled or disabled on nonstack port 
interfaces.
For more information, see the 
To disable UplinkFast on the switch and all its VLANs, use the no spanning-tree uplinkfast global 
configuration command.
Enabling BackboneFast
You can enable BackboneFast to detect indirect link failures and to start the spanning-tree 
reconfiguration sooner.
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
spanning-tree uplinkfast [max-update-rate 
pkts-per-second]
Enable UplinkFast.
(Optional) For pkts-per-second, the range is 0 to 32000 packets per 
second; the default is 150.
If you set the rate to 0, station-learning frames are not generated, 
and the spanning-tree topology converges more slowly after a loss 
of connectivity. 
When you enter this command, CSUF also is enabled on all 
nonstack port interfaces.
Step 3
end
Return to privileged EXEC mode.
Step 4
show spanning-tree summary
Verify your entries.
Step 5
copy running-config startup-config
(Optional) Save your entries in the configuration file.