Cisco Systems 3130 User Manual

Page of 1226
 
20-3
Cisco Catalyst Blade Switch 3130 for Dell Software Configuration Guide
OL-13270-01
Chapter 20      Configuring Flex Links and the MAC Address-Table Move Update Feature
Understanding Flex Links and the MAC Address-Table Move Update
Figure 20-2
VLAN Flex Links Load Balancing Configuration Example
MAC Address-Table Move Update
The MAC address-table move update feature allows the switch to provide rapid bidirectional 
convergence when a primary (forwarding) link goes down and the standby link begins forwarding traffic.
In 
, switch A is an access switch, and ports 1 and 2 on switch A are connected to uplink 
switches B and D through a Flex Link pair. Port 1 is forwarding traffic, and port 2 is in the backup state. 
Traffic from the PC to the server is forwarded from port 1 to port 3. The MAC address of the PC has 
been learned on port 3 of switch C. Traffic from the server to the PC is forwarded from port 3 to port 1. 
If the MAC address-table move update feature is not configured and port 1 goes down, port 2 starts 
forwarding traffic. However, for a short time, switch C keeps forwarding traffic from the server to the 
PC through port 3, and the PC does not get the traffic because port 1 is down. If switch C removes the 
MAC address of the PC on port 3 and relearns it on port 4, traffic can then be forwarded from the server 
to the PC through port 2.
If the MAC address-table move update feature is configured and enabled on the switches in 
 
and port 1 goes down, port 2 starts forwarding traffic from the PC to the server. The switch sends a MAC 
address-table move update packet from port 2. Switch C gets this packet on port 4 and immediately 
learns the MAC address of the PC on port 4, which reduces the reconvergence time. 
You can configure the access switch, switch A, to send MAC address-table move update messages. You 
can also configure the uplink switches B, C, and D to get and process the MAC address-table move 
update messages. When switch C gets a MAC address-table move update message from switch A, 
switch C learns the MAC address of the PC on port 4. Switch C updates the MAC address table, 
including the forwarding table entry for the PC. 
Switch A does not need to wait for the MAC address-table update. The switch detects a failure on port 1 
and immediately starts forwarding server traffic from port 2, the new forwarding port. This change 
occurs in 100 milliseconds (ms). The PC is directly connected to switch A, and the connection status 
does not change. Switch A does not need to update the PC entry in the MAC address table.
Switch A
Uplink
switch B
gi2/0/6
Forwarding
gi2/0/8
Not Forwarding
Uplink
switch C
201398