Cisco Systems 3130 User Manual

Page of 1226
 
20-9
Cisco Catalyst Blade Switch 3130 for Dell Software Configuration Guide
OL-13270-01
Chapter 20      Configuring Flex Links and the MAC Address-Table Move Update Feature
Configuring Flex Links and MAC Address-Table Move Update
When a Flex Link interface comes up, VLANs preferred on this interface are blocked on the peer 
interface and moved to the forwarding state on the interface that has just come up. In this example, if 
interface Gi2/0/6 comes up, VLANs preferred on this interface are blocked on the peer interface Gi2/0/8 
and forwarded on Gi2/0/6.
Switch# show interfaces switchport backup
Switch Backup Interface Pairs:
Active Interface        Backup Interface        State
------------------------------------------------------------------------
GigabitEthernet2/0/6    GigabitEthernet2/0/8    Active Up/Backup Standby
Vlans Preferred on Active Interface: 1-50
Vlans Preferred on Backup Interface: 60, 100-120
Switch# show interfaces switchport backup detail
Switch Backup Interface Pairs:
Active Interface        Backup Interface        State
------------------------------------------------------------------------
FastEthernet1/0/3       FastEthernet1/0/4       Active Down/Backup Up
Vlans Preferred on Active Interface: 1-2,5-4094
Vlans Preferred on Backup Interface: 3-4
Preemption Mode  : off
Bandwidth : 10000 Kbit (Fa1/0/3), 100000 Kbit (Fa1/0/4)
Mac Address Move Update Vlan : auto
Configuring the MAC Address-Table Move Update Feature
This section contains this information:
Configuring a switch to send MAC address-table move updates
Configuring a switch to get MAC address-table move updates
Beginning in privileged EXEC mode, follow these steps to configure an access switch to send MAC 
address-table move updates:
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
interface interface-id
Specify the interface, and enter interface configuration 
mode. The interface can be a physical Layer 2 interface or 
a port channel (logical interface). The port-channel range 
is 1 to 48.
Step 3
switchport backup interface interface-id
or
switchport backup interface interface-id mmu 
primary vlan 
vlan-id
Configure a physical Layer 2 interface (or port channel), 
as part of a Flex Link pair with the interface. The MAC 
address-table move update VLAN is the lowest VLAN ID 
on the interface.
Configure a physical Layer 2 interface (or port channel) 
and specify the VLAN ID on the interface, which is used 
for sending the MAC address-table move update. 
When one link is forwarding traffic, the other interface is 
in standby mode.