Chapter 3      Assigning the Switch IP Address and Default Gateway
Assigning Switch Information
The normal boot process involves the operation of the boot loader software, which performs these 
activities:
Performs low-level CPU initialization. It initializes the CPU registers, which control where physical 
memory is mapped, its quantity, its speed, and so forth.
Performs power-on self-test (POST) for the CPU subsystem. It tests the CPU DRAM and the portion 
of the flash device that makes up the flash file system.
Initializes the flash file system on the system board.
Loads a default operating system software image into memory and boots up the switch.
The boot loader provides access to the flash file system before the operating system is loaded. Normally, 
the boot loader is used only to load, uncompress, and start the operating system. After the boot loader 
gives the operating system control of the CPU, the boot loader is not active until the next system reset 
or power-on.
The boot loader also provides trap-door access into the system if the operating system has problems 
serious enough that it cannot be used. The trap-door mechanism provides enough access to the system 
so that if it is necessary, you can format the flash file system, reinstall the operating system software 
image by using the Xmodem Protocol, recover from a lost or forgotten password, and finally restart the 
operating system. For more information, see the 
 and the 
.
Note
You can disable password recovery. For more information, see the 
.
Before you can assign switch information, make sure you have connected a PC or terminal to the console 
port or a PC to the Ethernet management port, and make sure you have configured the PC or 
terminal-emulation software baud rate and character format to match these of the switch console port:
Baud rate default is 9600.
Data bits default is 8.
Note
If the data bits option is set to 8, set the parity option to none.
Stop bits default is 1.
Parity settings default is none.
Assigning Switch Information
You can assign IP information through the chassis management controller (CMC) GUI or manually.
If the switch reboots, it uses the IP address, subnet mask, and gateway in the saved configuration file.
The switch stack is managed through a single IP address. The IP address is a system-level setting and is 
not specific to the stack master or to any other stack member. You can still manage the stack through the 
same IP address even if you remove the stack master or any other stack member from the stack, provided 
there is IP connectivity.