3com 8807 User Manual

Page of 104
12
C
HAPTER
 1: P
RODUCT
 O
VERVIEW
Switch 8814
Figure 6   Switch 8814 slots
The Switch 8814 chassis provides 14 slots in its board area: The middle two 
accommodate fabric modules, which can operate in 1+1 redundancy mode; 
the remaining 12 accommodate I/O or application modules, which you can 
select from various available models. All modules in this area are 
hot-swappable.
At the bottom of the chassis is the power area that can accommodate one PoE 
entry module and two PSUs. The two PSUs are online-swappable. The switch 
supports AC power inputs.
On the right of the chassis is the fan area that contains two vertical 
hot-swappable fan trays. The fan trays draw and exhaust air from left to right.
Backplane
The backplane of the Switch 8800 Family allows high-speed data exchange 
between fabrics and I/O modules, as well as the exchange of various management 
and control signals in the system.
Functions
The following are the main functions of the backplane:
Providing communication channels for signal exchange between boards
Supporting board hot-swapping
Supporting auto-discovering boards in slots
Connecting PSUs, distributing power and providing monitor channels to 
various components (PSUs, fabrics and I/O modules) in the chassis.
Structure
Switch 8807
Fabric
Fabric
I/O Module
I/O Module
I/O Module
I/O Module
I/O Module
I/O Module
I/O Module
I/O Module
I/O Module
I/O Module
I/O Module
I/O Module
AC PSU
PoE
entry
AC PSU
Fa
n
 tr
a
y
 1
F
a
n
 tr
a
y
 2