Enterasys Networks 2G4072-52 User Manual

Page of 70
Connecting to the Network
3-12 Installation
Figure 3-11  Cable Connection to LC03 Fiber-Optic Connectors
3.
Verify a link exists by checking that the port RX LED is on (flashing amber, blinking 
green, or solid green). If the RX LED is off, perform the following steps until it is on:
a.
Verify the device at the other end of the segment is ON and linked to the segment.
b. If there are separate fiber‐optic connections on the other device, check the 
crossover of the cables. Swap the cable connections if necessary.
c.
Check that the fiber‐optic connection meets the dB loss and cable specifications 
outlined in the Cabling Guide for multimode fiber‐optic cabling. To obtain this 
document, refer to 
If a link has not been established, refer to 
 for LED troubleshooting details. If 
a problem persists, refer to 
on page xviii for support.
4.
Repeat steps 1 through 3, above, until all connections have been made.
5.
Plug the other end of the cable into the appropriate port on the other device. Some 
cables may be terminated at the other end with two separate connectors, one for each 
fiber‐optic strand. In this case, ensure that the transmit fiber‐optic strand is connected 
to the receive port and the receive fiber‐optic strand to the transmit port.
Port slot
Release tab
Receive LED (TX)
Mini-GBIC-LC03 cable connector
Transmit LED (RX)
13
14
15
16
17
18
19
20
Á
2G4072-52
Â
À
Ä
Ã