Enterasys Networks 2G4072-52 User Manual

Page of 70
Overview of Shutdown Procedure
4-6 Troubleshooting
Figure 4-2  RESET Button
Recommended Shutdown Procedure Using RESET Button
Before shutting off power to a 2G4072‐52,
press or tap on its RESET button for less than 1 second.
Its CPU LED changes from solid green to blinking between green and amber, indicating 
that the 2G4072‐52 is shutting down. At the end of the shutdown routine, the CPU LED 
changes to a 67%/33% sequence of amber/off, respectively, indicating the system is in a 
halt state. At this time it is safe to restart the 2G4072‐52.
When you initiate a controlled shutdown with the RESET button, you have 60 seconds 
from the time the CPU starts flashing amber/off until the device automatically restarts.
Last Resort Shutdown Procedure Using RESET Button
To reset a 2G4072‐52 without it performing an orderly shutdown routine, 
press and hold the RESET button for approximately 6 seconds.
RESET
CONSOLE
CPU
PWR
GROUP
SELECT
GROUP 3
GROUP 2
GROUP 1
Reset button
Caution: This method of shutting down a Enterasys Matrix N SA 2G4072-52 is not 
recommended except as a last resort, because all processes currently running on the 
module will be interrupted resulting in loss of frames.
Precaución: No se recomienda utilizar este método para apagar los módulos Enterasys 
Matrix N SA 2G4072-52. Recurra a él sólo como último recurso, puesto que interrumpe 
todos los procesos del módulo en funcionamiento, lo que podría resultar pérdidas de 
frames.