Alarm Configuration
4-8
Basic Alarm Configuration
7.
In the Rising Action field, click to select the action you want your device to 
take in response to a rising alarm: Enable Port, Disable Port, or None. Note 
that this action enables or disables only 
bridging at the specified port, and not 
the interface itself.
For more information on how actions are triggered, see 
, on 
.
8.
Click in the Falling Threshold field, and enter the low threshold value for this 
alarm. Remember, compared values are always relative, or delta values (the 
difference between the value counted at the end of the current interval and 
the value counted at the end of the previous interval); be sure to set your 
thresholds accordingly.
When configuring a Kilobits alarm, NetSight Element Manager converts 
octets into kilobits (units of 125 bytes, or octets) for you; for example, to set a 
falling threshold of 625 octets, enter a threshold value of 5.
9.
In the Falling Action field, click to select the action you want your device to 
take in response to a falling alarm: Enable Port, Disable Port, or None. Note 
that this action enables and disables only 
bridging at the specified port, and 
not the interface itself.
For more information on how actions are triggered, see How Rising and 
Falling Thresholds Work
.
10. Click the Apply button to set your changes. If you have made any errors in 
configuring alarm parameters (using an invalid rising or falling threshold, for 
example, or neglecting to supply a polling interval), either an error window 
with the appropriate message will appear, or a beep will sound and the cursor 
will blink in the field which contains the error. Correct the noted problem(s), 
and click Apply again.
Once you click the Apply button, the configured alarm parameters will be set for 
every selected interface, and the alarms will automatically be enabled; the list box 
display will also refresh to reflect these changes.
To configure additional alarms, or alarms of a different type, select the 
appropriate alarm variable at the top of the window, highlight the appropriate 
interface(s), and repeat the procedures outlined above.
TIP
The Actions fields will be grayed out for devices that do not support the proprietary 
Actions MIB.