Enterasys Networks 2S4082-25-SYS User Manual

Page of 108
Overview
1-6 Introduction
Redundant Power Supplies
The Enterasys NAC Controller supports two fixed, auto‐ranging redundant AC power supply 
modules. For power supply specifications, refer to “
Power Supply LANVIEW LEDs
Power supply status is indicated by LANVIEW
®
 LEDs located on the front panel of the chassis. 
Each power supply utilizes a single LED to monitor and detect power supply failure and 
redundancy status. Refer to 
, 
, for a full 
explanation of the power supply LEDs and their definitions.
Power Supply Status Through System Management
The Enterasys NAC Controller power supplies report information to the NAC Controller PEP 
installed in the chassis regarding their present operating status. This information includes the 
following:
Power Supply ID (PS1, PS2)
Power Supply Status (normal/fault)
Power Supply Redundancy indication
Refer to the Enterasys Matrix DFE‐Diamond/Platinum Series Configuration Guide for instructions on 
how to access power supply status information via Local Management.
Auto-Ranging Power Supplies
The Enterasys NAC Controller power supplies automatically adjust to the input voltage and 
frequency, which allows for an input voltage of 100 to 240 Vac, and a frequency between 50 and 
60 Hz. Refer
 
to the operating specifications in 
. No additional adjustments are 
necessary. For installations in North America, two 15 A power cords are required. Refer to 
” on page 3‐5 for more details.
Power Supply Replacement
Power supplies in the Enterasys Matrix N1 chassis are fixed and, as such, are not considered 
field‐replaceable units.
If a power supply must be replaced, contact Technical Support for information (refer to 
Chassis Cooling System
The Enterasys Matrix N1 chassis backplane supports six 2‐wire 12v fans. General fan failure is 
detected at the chassis backplane and the status is relayed to the module using the FTM2 
connector.
The fans have one LANVIEW LED located on the front of the unit. This LED indicates the status of 
the fans, either normal or fault condition. Since the fans are built into the chassis, there is no 
support for a ‘Fan Present’ indicator. Refer to 
, for a full description of fan LED states.