Dimensions and Wire Ranges
®
Generac Power Systems, Inc. • S45 W29290 HWY. 59,  Waukesha, WI 53189 • generac.com
©2013 Generac Power Systems, Inc.  All rights reserved.  All specifications are subject to change without notice.  Bulletin 0199020SBY-C  Printed in U.S.A.  04/17/13
50-100 Amps  
Pre-Wired Switch
®
Functions
Specifications
Features
•  Electrically operated, mechanically-held contacts for fast, positive connections.
•  Rated for all classes of load, 100% equipment rated, both inductive and resistive.
• 2 pole, 250 VAC contactors.
• 30 millisecond transfer time.
• Dual coil (100A) and single coil (50A) designs.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA 1 (indoor rated) enclosure is standard.
• 5 Year Limited Warranty.
All timing and sensing functions originate in the generator controller.
 
Utility voltage drop-out ......................................................................................................................................................................................................................<60%
 
Timer to generator start ..................................................................................................10 second factory set, adjustable between 2-1500 seconds by a qualified dealer*
 
Engine warm up delay .................................................................................................................................................................................................................5 seconds
 
Standby voltage sensor ..................................................................................................................................................................................................60% for 5 seconds
 
Utility voltage pickup .........................................................................................................................................................................................................................>80%
 
Re-transfer time delay ...............................................................................................................................................................................................................15 seconds
 
Engine cool-down timer ............................................................................................................................................................................................................60 seconds
 Exerciser 
 .............................................................................................................................................................................................................. 12 minutes every 7 days
 
The transfer switch can be operated manually without power applied.
 
*When used in conjunction with units utilizing Evolution™ controls
Model
RTG10EZA1
RTG12EZA1
RTG14EZA1
RTG16EZA1
Voltage
120/240, 1ø
120/240, 1ø
120/240, 1ø
120/240, 1ø
Amps
50
50
100
100
Circuits,  50A, 240V
1
 
40A, 240V
1
1
1
 
30A, 240V
1
1
 
20A, 240V
1
1
1
 
20A, 120V
3
3
6
5
 
15A, 120V
3
5
4
5
Phase
1
Rated AC Frequency
60 Hz
Enclosure Material
Steel
Enclosure Type
NEMA 1
Withstand Rating (Amps)
10,000
Lug Range
1/0 - #14
Load Transition Type
Open Transition
30' Whip Conductor Gauges (Hot, Neutral, Ground, Control)
8, 8, 10, 18
6, 6, 8, 18
H1
W1
W2
H2
Pre-
Wired Switch
Mechanical Dimensions
Amps
Height
Width
Depth
H1
H2
H3
W1
W2
W3
50*
18.5 in.
22.5 in.
22 in.
10.5 in.
15.4 in.
14.4 in.
3.8 in
470mm
571.8mm
558.8mm
266.7
392mm
366mm
97.5mm
100
23.5 in.
26.4 in.
N/A
8.3 in.
12.6 in.
N/A
6.3 in.
597mm
671.7mm
N/A
211mm
320.7mm
N/A
159.6mm
Wire Ranges
Amps
Conductor Lug
Neutral Lug
Ground Lug
50
1/0 - #14
2/0 - #14
2/0 - #14
100
2/0 - #14
2/0 - #14
2/0 - #14
50 Amp Switch
100 Amp Switch
H1
W1
W2
H2
*Note: The 50 Amp switch is flush mountable. H1 and W1 refer to mounting hole spacing. 
H2 and W2 are cover dimensions. H3 and W3 (not shown in diagram) are the enclosure 
dimensions without cover.