C/E-R-TX-FX-01 IN THE NETWORK
Recessed switches located on each side of the media converter are used to
configure the media converter for the network. 
NOTE: Switch labels are located
AT TOP of C/E-R-TX-FX-01 media converter.
MDI/MDI-X SWITCHES
(One for each RJ-45 port - located one on each side of media
converter) Allows straight-through twisted-pair cable to be
used for crossover 100BASE-TX connections.
4-POSITION SWITCH (3rd switch not used)
Auto-negotiation (UP) Detects and adapts to line speed and
operating mode of attached device.
Full/Half-duplex (UP) Allows an attached full-duplex station to
transmit and receive simultaneously. (DOWN) Allows an
attached station to transmit and receive sequentially.
Port Select Timer (UP) Selects timer duration of eleven (11) seconds. 
(DOWN) Selects timer duration of five (5) seconds. 
TECHNICAL SPECIFICATIONS
Standards
IEEE 802.3
Case Dimensions
5.7" x 3.0" x 1.8"
(145mm x 76mm x 46mm)
Shipping Weight
3 pounds
(1.4 kilograms)
Delay
400nsec round trip
Environment
Temperature:
0-50°C (32° to 122° F )
Humidity
10-90%, non condensing 
Altitude
0-10,000 feet
Power Supply Requirements Replace power supply with only the equivalent
input rating (see below) and output rating (unregulated 9-24VDC, 5.5W).
TN PN
Requirement
Location
3507
240 volts, 50 hertz
United Kingdom
3342
230 volts, 50 hertz
Europe
3340
120 volts, 60 hertz
USA/Canada/Mexico
3346
100 volts, 50-60 hertz
Japan
3511
240 volts, 50 hertz
Australia
3537
(with power cord: 3522) South Africa
Warranty
Lifetime
NOTE: Media Converter Slide-in-Modules can be installed in any
installation slot, in any order.
DECLARATION OF CONFORMITY
Name of Mfg:
Transition Networks 
6475 City West Parkway, Minneapolis MN 55344 USA
Model:
Redundant Fast Ethernet
Media Converters
Part Number:
C/E-R-TX-FX-01 
Regulation:
EMC Directive 89/336/EEC
Purpose:  To declare that the C/E-R-TX-FX-01 to which this declaration refers is
in conformity with the following standards.
EMC-CISPR 22: 1985 Class A;  EN 55022: 1988 Class A;  EN 50082-1:1992;
EN 60950 A4:1997;  IEC 801.2, IEC 801.3, and IEC 801.4;  IEC 950
I, the undersigned, hereby declare that the equipment specified above conforms to the
above Directive(s) and Standard(s).
_May 1, 1999_____
Stephen Anderson, Vice-President of Engineering
Date
2 kilometers - multimode
20 kilometers - singlemode
100 meters 
100 meters 
MDI switch setting
PST (DOWN) switch setting 
MDI switch setting
PST (UP) switch setting 
SWITCH
SWITCH
Do NOT connect media
converters between hubs. 
Install no more than two (2)