Moxa Technologies EDS-405A User Manual

Page of 82
EDS-408A/405A Series User’s Manual 
Featured Functions 
 
3-17
Admin Auth. Type (for SNMP V1, V2c, V3, and V3 only) 
Setting 
Description 
Factory Default 
No-Auth 
Use admin account to access objects. 
No authentication 
No 
MD5- 
Auth 
Provide authentication based on the 
HMAC-MD5 algorithms. 8-character 
passwords are the minimum requirement 
for authentication. 
No 
SHA- 
Auth 
Provide authentication based on the 
HMAC-SHA algorithms. 8-character 
passwords are the minimum requirement 
for authentication. 
No 
Admin Data Encryption Key (for SNMP V1, V2c, V3, and V3 only) 
Setting 
Description 
Factory Default 
Enable 
8-character data encryption key is the 
minimum requirement for data encryption. 
Maximum 30-character encryption key 
No 
Disable 
No data encryption 
No 
User Auth. Type (for SNMP V1, V2c, V3 and V3 only) 
Setting 
Description 
Factory Default 
No-Auth 
Use the admin or user account to access 
objects. No authentication. 
No 
MD5-Auth 
Provide authentication based on the 
HMAC-MD5 algorithms. 8-character 
passwords are the minimum requirement 
for authentication. 
No 
SHA-Auth 
Provide authentication based on the 
HMAC-SHA algorithms. 8-character 
passwords are the minimum requirement 
for authentication. 
No 
User Data Encryption Key (for SNMP V1, V2c, V3 and V3 only) 
Setting 
Description 
Factory Default 
Enable 
8-character data encryption key is the 
minimum requirement for data 
encryption. Maximum 30-character 
encryption key. 
No 
Disable 
No data encryption 
No 
Trap Settings 
Trap Server IP/Name 
Setting 
Description 
Factory Default 
IP or Name 
Enter the IP address or name of the Trap 
Server used by your network. 
None