EDS-408A/405A Series User’s Manual 
Featured Functions 
 
3-23
Configuring “Turbo Ring” and “Turbo Ring V2” 
Use the Communication Redundancy page to configure select “Turbo Ring” or “Turbo Ring 
V2.” Note that configuration pages for these two protocols are different. 
Configuring “Turbo Ring” 
 
Explanation of “Current Status” Items 
Now Active 
Shows which communication protocol is in use: Turbo RingTurbo Ring V2RSTP, or none
Master/Slave 
Indicates whether or not this EDS is the Master of the Turbo Ring. (This field appears only when 
selected to operate in Turbo Ring or Turbo Ring V2 mode.) 
NOTE 
The user does not need to set the master to use Turbo Ring. If no master is set, the Turbo Ring 
protocol will assign master status to one of the EDS units in the ring. The master is only used to 
determine which segment serves as the backup path. 
Redundant Ports Status (1st Port, 2nd Port) 
Ring Coupling Ports Status (Coupling Port, Coupling Control Port) 
The “Ports Status” indicators show Forwarding for normal transmission, Blocking if this port is 
connected to a backup path and the path is blocked, and Link down if there is no connection.