EDS-408A/405A Series User’s Manual 
Featured Functions 
 
3-55
Using Event Log 
 
 
Bootup 
This field shows how many times the EDS has been rebooted or cold 
started. 
Date 
The date is updated based on how the current date is set in the “Basic 
Setting” page. 
Time 
The time is updated based on how the current time is set in the “Basic 
Setting” page. 
System Startup Time  The system startup time related to this event. 
Events 
Events that have occurred. 
 
Events are logged in the EDS-408A/405A Event Log when the following events occur: 
1.  Cold start 
2.  Warm start 
3.  Configuration Change Activated 
4.  Power Transition from OFF to ON or from ON to OFF 
5.  Authentication Fail 
6.  Topology Changed 
7.  Master Setting is Mismatched 
8.  Port Traffic Overload 
9.  Port Link from OFF to ON or from ON to OFF 
Using Syslog 
This function provides the event logs for the syslog server. The function supports 3 configurable 
syslog servers and syslog server UDP port numbers. When an event occurs, the event will be sent 
as a syslog UDP packet to the specified syslog servers.