10.3.4 Output Service
As with POWER, JES2 supports line-mode printers, whereas PSF controls AFP
Printers. (See Chapter 11, “Advanced Function Printing and Print Services
Facility/MVS” on page 235 for AFP printing.)
Table 13 (Page 1 of 2). POWER/JES2 Output Service Comparison
Output Service
Function
POWER
JES2
JES2 Comments
Local Line Printer
(3211, 4245, 4248)
Y
Y
See 10.3.4.1, “Printers
Supported” on
page 216 
Page Mode Printer
(3900, 3820, etc.)
Y
Y
v i a PSF/MVS
Local Diskette
Y
N
(no longer supported
in OS/390)
Remote BSC & SNA
Printers & Punches
Y
Y
Tape Spooling
Y
N
See 10.1.1.3, “Tape
Spooling” on
page 208 
Interactive User
Y ICCF
Y
TSO/E Output or SDSF
Other NJE Node
Y
Y
Output Classes
A - Z, 0 - 9
A - Z, 0 - 9
Output Priority Ranges
0 - 9
0 - 15
Output Disposition
(D/H/K/L)
Y
Y
See 10.3.4.7, “Output
Disposition” on
page 217 
Segmentation v i a
JCL/JECL
Y (RBS
Parm.)
Y
// DD SEGMENT=
(line mode only)
Segmentation v i a
Program Control
Y (SEGMENT
m a c r o o r
LFCB
dynalloc)
Y
FREE=CLOSE o r
S P I N = U N A L L O C
dynalloc parm or
SETPRT
Output Separation
between Jobs
Y
Y
See 10.1.1.5,
“ S e p a r a t o r Page
Difference” on
page 208
User Info on Sep. Page
Y
Y
Use Exit 1 and/or 15
or JESNEWS
Forms Number
Y (1-4 chars)
Y (1-8 chars)
Forms Control Buffer
(FCB)
Y (1-8 chars)
Y (1-4 chars)
See 10.3.4.8, “FCB
Naming Differences”
on page 217 
Universal Character
Set (UCS)
Y (1-8 chars)
Y (1-4 chars)
See 10.3.4.9, “UCS
Naming Conventions”
on page 218 
Multiple Destinations
(RJE, NJE) via JCL
N
Y
Printer Forms
A l i g n m e n t
Y (PSETUP
cmd)
Y
See 10.1.1.4, “Printer
Forms Alignment via
PSETUP” on page 208 
Chapter 10. POWER and JES2
215