RX900 S1
Maintenance Manual
55
Power supply
Ê
Press the two plastic clips together as indicated by the arrows and remove 
the dummy module.
V
CAUTION!
Keep the dummy module for future use. If the power supply unit is 
removed and not replaced with a new unit, the dummy module must be 
reinstalled due to cooling, to comply with applicable EMC regulations 
(regulations on electromagnetic compatibility), and to protect against fire.
5.1.4
Installing a power supply unit
Figure 12: Installing a power supply unit
Ê
Slide the power supply unit into the empty bay until it clicks into place.
I
Make sure that the power supply unit engages correctly in the 
mounting location and is locked in position. This is the only way to 
prevent the power supply unit from sliding out of its mountings and 
being damaged during transportation.