Fujitsu RX600 S6 User Manual

Page of 134
46
Operating Manual
 RX600 
S6
Hardware installation
– You must ensure that the safety mechanisms on the server, e.g. stoppers or 
retaining systems, are functioning correctly.
– The shape of the rack support uprights must ensure that the support 
systems can be bolted to the front.
The support systems have a linear alignment feature to ensure that they can 
be adjusted to different rack depths.
– No cable management support (delivered with the mounting kit).
– Climatic conditions:An unobstructed air intake in the rack front and air 
discharge in the rear cover of the rack are essential for ventilation of the 
installed server.
In general, the ventilation concept ensures that the necessary cooling is 
achieved by the horizontal self-ventilation of the installed devices (air flow 
from the front to the rear). 
– Power supply: For installation in third party racks, you must ensure that the 
appropriate socket strips are present.
4.2.2
Mounting the server into the rack
I
For information on mounting the server in the rack please refer to the 
mounting instructions provided with the Rack Mounting Kit. Further 
information you can find in the manual of your rack system.