iRMC S2 SEL Entries and SC2 MIB Traps
3.7
iRMC S2 SEL entries relayed as SC2 MIB 
traps
I
The following table applies to PRIMERGY systems manufactured 
in 2009 or later.
If the iRMC S2 writes an event to the System Event Log (SEL), in some cases 
an SNMP trap is triggered. The following table shows the correlation between 
the iRMC S2 entries in the SEL and the traps they trigger.
I
Not all iRMC S2 entries made in the SEL trigger an SNMP trap. Some 
trigger the same trap.
Error 
code
iRMC S2 SEL entry
Trap text
Trap 
no.
Trap name
000011
System event log 
(SEL) warning 
threshold exceeded
The System Event 
Log for cabinet XY at 
server XY has 
exceeded XY 
percent of its 
capacity.
2101 sc2TrapMessa
geLogWarning
040000
’FAN XY’: Fan failed
Fan ’FAN XY’ failed 
in cabinet XY of 
server XY.
2014 sc2TrapFan
Failed
040001
’FAN XY’: Fan is 
working
Fan ’FAN XY’ was 
added into cabinet 
XY of server XY.
2010 sc2TrapFan
Added
Fan ’FAN XY’ in 
cabinet XY of server 
XY is working again.
2012 sc2TrapFanOk
040002
’FAN XY’: Fan 
prefailure
Fan ’FAN XY’ will fail 
in near future in 
cabinet XY of server 
XY.
2013 sc2TrapFan
Critical
Table 4: iRMC S2 SEL entry - SC2 MIB trap