Fujitsu V6.00 User Manual

Page of 174
48
 
 ServerView 
Event 
Manager
Alarm rules
The alarm list in the bottom section of the window shows via checkboxes which 
alarms are assigned to the alarm rule. It also shows the names of the alarms 
(
Alarm Name
), their severity (
Severity
), their MIB file (
MIB
), in which the alarm is 
defined, and their trap name (
Identifier
).
Alarms which are assigned to the selected alarm rule are indicated by selected 
checkboxes. You can select or deselect a checkbox by clicking it. 
Clicking the 
Apply
 button saves the changed settings for the alarm rule. The 
value of the 
Assigned
 counter then matches the value of the 
Checked
 counter. 
All alarms in the alarm list can be sorted or filtered according to different criteria. 
This allows only certain alarms to be displayed.
You sort the alarms by clicking the relevant column in the header of the alarm 
list. You can sort them alphabetically by 
Alarm Name
Severity
MIB
 or 
Identifier
You filter the alarms by clicking the corresponding filter icons 
 in the header 
of the alarm list. 
You can filter them according to selected alarms (selected checkboxes)
, Alarm 
Name, Severity
 or 
MIB
. Clicking the filter icon opens the respective associated 
dialog box. If, for example, you have selected 
Severity
, the dialog box shows the 
error severities, which you can then select. You make your selection and then 
confirm it with 
OK.
 Depending on your selection, the window then shows only 
the filtered alarms. An active filter is indicated by a blue filter icon.
In the standard filter (
Standard
), all selection elements are selected via 
checkboxes. In the customized filter (
Customize
) you make your selection either 
by entering it directly (e.g. MINOR) or using the asterisk as a wildcard. With 
Severity, for example, specifying M* selects the severities Major and Minor.