Alarm configuration example
4.12
Alarm configuration example
This section explains a typical example of alarm configuration.
Purpose
When an event whose severity is critical occurs on the 
ALARMTEST
 server, a 
mail is sent to the administrator (
admin@test.co.jp
).
Requirements
ServerView agent is running on the server, and the server is registered as a 
management target in ServerView Operations Manager on the same 
network.
Test traps from the ServerView agent to ServerView Operations Manager 
are functioning normally.
ServerView Operations Manager can access the SMTP server 
(111.222.3.20) while it is in operation.
Setting procedure
Ê
Perform one of the following operations.
When operating from the ServerView Operations Manager start window:
Click 
Alarm Configuration
.
When operating from the individual function windows:
Click 
Event Management – Alarm Configuration
 in the menu bar at the top 
of the window.
The 
Manage Alarm Rules
 window opens.
Ê
Click 
Add
The 
New Name
 dialog box opens.
Ê
Enter e.g. 
CriticalMail
 in the 
New Name
 dialog box and click 
OK
.
Ê
Click 
Apply
, then click 
Next
.
The 
Assign Servers
 window opens.
Ê
Select the 
ALARMTEST
 server in the server list, and click the > button.